Flow Bench Data - Article by Kevin Bracken |
ducatimeccanica.com - home |
|
|||
Set-up | CFM | ||
Mk II Amal |
30 mm bare with short inlet bell 30 mm w/ stock triumph air box 30 mm stock box, air horns removed 30 mm stock box, JRC-type filters 30 mm stock box, no filters 30 mm K&N RU-132, 4.5" long, large oval 30 mm K&N RU-115, 6" long, small oval 30 mm K&N RU-114, 5" long, smal oval 34 mm bare with short inlet bell 34 mm stock box, JRC-type filters 34 mm K&N RU-132, 4.5" long, large oval 34 mm K&N RU-115, 6" long, small oval 34 mm K&N RU-114, 5" long, smal oval 34 mm w/ AMAL velocity stack 34 mm vel. Stack + K&N RU-132 34 mm vel. Stack + K&N RU-115 34 mm vel. Stack + K&N RU-114 |
109.68 88.76 96.87 98.74 107.36 110.10 108.43 108.43 140.82 121.82 140.55 138.31 134.95 137.96 134.83 132.96 132.40 |
|
Bing CV |
32 mm bare + adaptor tube (TRI) 32 mm K&N RU-132 32 mm K&N RU-115 32 mm K&N RU-114 |
119.96 119.96 119.96 119.96 |
|
Dellorto pumper |
36 mm bare, short stack 36 mm bare, long stack 36 mm RU-132 w/ stack inside 36 mm RU-132 no stack |
153.95 158.97 157.30 147.82 |
|
All testing done on Jerry Branch's flow bench All testing done at 12 inches water Each carburetor was fitted to flow bench directly, without a head Flow data corrected for atmospheric temperature |
|||
|